Brands / Metered & Switched PDU / 87-3300-18
87-3300-18
Part Number: 87-3300-18

30-fold switched and metered PDU, 3-phase

Model Number 87-3300-18
Input Current 3x 16 A, 110-400 V
Number of Power Ports 30
Control Interface LAN
Environment Monitoring 2 sensor connectors
Installation 19 inch racks, 0 HU
Power Port Type 24x IEC C13, 6x IEC C19
Brand Gude Systems

Contact for Pricing

Contact Us

Key Features

General

Event and schedule controlled switching
Precise current metering of up to 9 electrical units per phase
2 connectors for plug-and-play sensors
No height unit required due to vertical installation in the rack
Simple and quick mounting due to integrated mounting straps
NTP function can be activated

Switching Function

Each power port can be switched via HTTP(S), SNMP, ModbusTCP, Telnet, SSH and MQTT
Programmable on/off sequences for remote reboots (Remote Reboot)
Power ports can be switched when preset sensor thresholds are exceeded
Self-healing function thanks to 30-channel watchdog: Each power port can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second

Metering Function

Power consumption metering (kWh) with 2 energy counters: one counter counts consistently, the other counter is resettable
Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr), input-metered and per phase
2 connectors for combined plug-and-play sensors (temperature, humidity and air pressure) to prevent often occurring physical hazards like overheating and increased humidity or air pressure

Security

Long-life High-Inrush Relays prevent welding of relay contacts during inrush current peaks
Generation of status messages and alarms (e-mail, syslog, SNMP traps, MQTT, SSH, Telnet)
Encrypted e-mails (SSL, STARTTLS)
Access protection by IP access control
Support for the 802.1X standard for port authentication in the network
Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
Password protected access
Beeper for audible alarm when sensor limits are exceeded/deceeded

Operation

Easy-to-read LED display for displaying total current, IP address and sensor values
Firmware update via Ethernet during operation (no restart required)
Simple and flexible configuration via web browser, Windows or Linux program
Dynamic assignment of an IP address via DHCP or manual assignment of static IP address
Rapid commissioning thanks to free and reliable drivers from our technology partners

Technical Specifications

Technical Details
High-inrush Relay max. 4 sec: 30 A / max. 20 ms: 80 A
Measurement Current (A), Voltage (V), Phase angle, Power factor, Frequency (Hz), Active power (W), Apparent power (VA), Reactive power (VAr)
Security SSL (TLS 1.1, 1.2, 1.3), SSH
Mounting Vertical, 0 HU
Dimensions (LxWxH) 170 x 8 x 6.5 cm (including mounting brackets)
Weight Approx. 3.9 kg (including cable and plug: 6.7 kg)
Operating Temperature 0-50 °C
Storage Temperature -20 – 70 °C
Relative Humidity 0 – 95 % (non condensing)
Electrical Connections
Power Supply 1x CEE (max. 3x 16 A, 400 V)
Power Ports IEC C13 24x IEC C13 (max. 10 A)
Power Ports IEC C19 6x IEC C19 (max. 16 A)
Ethernet 1x RJ45 (10/100 Mbit/s)
Sensor Connectors 2x RJ45 for plug-and-play sensors
Order Codes
87-3300-18 30-fold switched and metered PDU, 3-phase
Scope of Delivery
Unit Expert Power Control 87-3300-18
Connection Cable 1x connection cable CEE Red (3P+N+PE), length: 2.5 m
More Info
More Info
More Info
← Back to Metered & Switched PDU