Brands / Metered & Switched PDU / 8021
8021
Part Number: 8021

4-fold switched and metered PDU

Model Number 8021
Input Current 16 A, 110-230 V
Number of Power Ports 4
Control Interface LAN
Environment Monitoring 2 sensor connectors
Installation 19-inch, 1 HU
Power Port Type IEC C13
Brand Gude Systems

Contact for Pricing

Contact Us

Key Features

8021-1: 4x IEC C13

General

Event and schedule controlled switching
Precise current metering of up to 9 electrical units and residual current
2 connectors for plug-and-play sensors
Simple and quick mounting due to integrated mounting straps
NTP function can be activated
Integrated overvoltage protection type 3

Switching Function

Each power port can be switched via HTTP(S), SNMP, ModbusTCP, Telnet, SSH, MQTT and serial interface
Programmable on/off sequences for remote reboots (Remote Reboot)
Power ports can be switched when preset sensor thresholds are exceeded
Self-healing function thanks to 4-channel watchdog: Each power port can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second
Zero Voltage Switching (ZVS) avoids high switching currents by switching at the zero crossing of the AC voltage

Metering Function

Power consumption metering (kWh) with 2 energy counters: one counter counts consistently, the other counter is resettable
Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
Metering of differential current type A (mA)
2 connectors for combined plug-and-play sensors (temperature, humidity and air pressure) to prevent often occurring physical hazards like overheating and increased humidity or air pressure

Security

Integrated type 3 overvoltage protection prevents damage to the device and connected loads
Long-life High-Inrush Relays prevent welding of relay contacts during inrush current peaks
Generation of status messages and alarms (e-mail, syslog, SNMP traps, MQTT, SSH, Telnet)
Encrypted e-mails (SSL, STARTTLS)
Access protection by IP access control
Support for the 802.1X standard for port authentication in the network
Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
Password protected access
Beeper for audible alarm when sensor limits are exceeded/deceeded

Operation

Easy-to-read LED display for displaying total current, IP address and sensor values
Firmware update via Ethernet during operation (no restart required)
Simple and flexible configuration via web browser, Windows or Linux program
Dynamic assignment of an IP address via DHCP or manual assignment of static IP address
Rapid commissioning thanks to free and reliable drivers from our technology partners

Technical Specifications

Technical Details
Overvoltage Protection Integrated type 3 (L-N, L/N-PE), status via network
High-inrush Relay max. 4 sec: 30 A / max. 20 ms: 80 A
Zero Voltage Switching ± 0.8 ms with temperature compensation
Measurement Current (A), Voltage (V), Phase angle, Power factor, Frequency (Hz), Active power (W), Apparent power (VA), Reactive power (VAr)
Residual Current Type A (mA)
Security SSL (TLS 1.1, 1.2, 1.3), SSH
Dimensions (LxWxH) 439 x 178 x 44 mm (without mounting brackets)
Weight Approx. 2.7 kg
Operating Temperature 0-50 °C
Storage Temperature -20 – 70 °C
Relative Humidity 0 – 95 % (non condensing)
Electrical Connections
Power Supply 1x IEC C20 (max. 16 A, 230 V)
8021-1 Power Ports 4x IEC C13 (max. 10 A)
Ethernet 1x RJ45 (10/100 Mbit/s)
Serial Interface 1x RS232 (Sub-D, 9-pin)
Sensor Connectors 2x RJ45 for plug-and-play sensors
Order Codes
8021-1 4x IEC C13
Scope of Delivery
Unit 4-fold switched and metered PDU-1
Power Cable 1x power supply cable (safety socket type F – IEC C19)
More Info